O2k and HRR: Difference between revisions

From Bioblast
(Redirected page to O2k high-resolution respirometry)
(Redirected page to Oroboros O2k)
Β 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
#REDIRECT [[O2k high-resolution respirometry]]
#REDIRECT [[Oroboros O2k]]
Β 
{{OROBOROS_header_page_name}}
:::: <big>'''[[Oxygraph-2k |OROBOROS Oxygraph-2k]] - unique for high-resolution respirometry (HRR)'''</big>
::::::::::: <big>'''O2k - tested and trusted'''</big>
[[File:OROBOROS-Concept.jpg|right|300px|link=O2k high-resolution respirometry |HRR]]
__TOC__
== OROBOROS INSTRUMENTS ==
[[Image:Logo_OROBOROS_INSTRUMENTS.jpg|left|120px|link=http://wiki.oroboros.at/index.php/OROBOROS_INSTRUMENTS |OROBOROS]]
Β 
[[OROBOROS INSTRUMENTS]] distributes the world-wide leading O2k-technology of high-resolution respirometry - '''O2k and HRR'''. The [[OROBOROS_Contact|OROBOROS Company]] is fully scientifically oriented, with emphasis on continuous innovation. The extension of the [[Oxygraph-2k]] (O2k) to the [[O2k-Fluorometer]] has set a new standard for O2k-MultiSensor approaches (see [[OROBOROS O2k-Catalogue]]). The O2k is established internationally, with [[O2k-Publications: Topics |Β»{{#ask:[[Category:Publications]][[Instrument and method::Oxygraph-2k]] |format=count}} O2k-Publications]] in the scientific literature. OROBOROS has organized more than 100 international [[OROBOROS_Events#Next_O2k-Workshops |O2k-Workshops]]. The [[O2k-Network]] includes more than 350 Reference Laboratories in 46 countries.
Β 
Β 
== The O2k for high-resolution respirometry ==
[[Image:O2k-Fluorometer.JPG|left|120px|link=http://wiki.oroboros.at/index.php/Oxygraph-2k |O2k]]
Β 
The OROBOROS Oxygraph-2k provides a unique high-resolution approach for the monitoring of cellular and mitochondrial respiratory function: [[high-resolution respirometry |high-resolution respirometry (HRR)]]. Considering mitochondria as the powerhouses of the cell, HRR introduced the concept of [[cell ergometry]]. Are your cells [[MitoFit]]?
Β 
HRR is applied [[O2k-Network |world-wide]] in areas ranging from fundamental bioenergetics to the analysis of mitochondrial and metabolic diseases, advancing the rapidly growing field of preventive mitochondrial medicine. Mitochondrial fitness needs to be monitored in a variety of age-related health risks, including cardiovascular and degenerative diseases, such as type 2 diabetes, neurodegenerative diseases (Alzheimer’s, Parkinson’s, Huntington’s), and several types of cancer.
Β 
Β 
Β 
[[File:OROBOROS MitoFit-Lab.jpg|left|240px|link=http://wiki.oroboros.at/index.php/OROBOROS_INSTRUMENTS |OROBOROS]]
HRR by the OROBOROS O2k is based on a radically different systems approach to polarographic measurement of oxygen dynamics. HRR rests on several tightly connected instrumental features and concepts integrated by the DatLab software, providing real-time display of oxygen concentration and respiration ([[oxygen flux]]). The mechanics, critical selection of materials, and state-of-the-art electronics provide the basis of signal stability of an optimized [[polarographic oxygen sensor]], in an electronically controlled thermal environment with high temperature stability. Calibrations and instrumental controls follow standard operating procedures, with highly automatic real-time analysis by the DatLab software. Scientific support is complementary to the approach of HRR.
Β 
Β 
Β 
== From the O2k to the Power-O2k ==
[[Image:Power-O2k.png|left|120px|link=http://wiki.oroboros.at/index.php/Power-O2k|Power-O2k]]
Multiple O2k-units are offered as a β€˜Power-O2k System’ for HRR combined with high-throughput - at high output.
Β 
:: ''More details? Consult'' [[Power-O2k]]

Latest revision as of 19:48, 8 July 2017

Redirect to:

Cookies help us deliver our services. By using our services, you agree to our use of cookies.