Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Scandurra 2010 Adv Exp Med Biol"

From Bioblast
Line 9: Line 9:
|discipline=Mitochondrial Physiology
|discipline=Mitochondrial Physiology
}}
}}
== Cited by ==
{{Template:Cited by Komlodi 2021 MitoFit AmR-O2}}
{{Labeling
{{Labeling
|area=Respiration, Instruments;methods
|area=Respiration, Instruments;methods
Line 19: Line 17:
|couplingstates=LEAK, ROUTINE, OXPHOS, ET
|couplingstates=LEAK, ROUTINE, OXPHOS, ET
|instruments=Oxygraph-2k
|instruments=Oxygraph-2k
|additional=Alert2020,
|additional=Alert2020, MitoFit 2021 AmR-O2
}}
}}
== Cited by ==
{{Template:Cited by Komlodi 2021 MitoFit AmR-O2}}
== O2k-Publications ==
== O2k-Publications ==
* [[O2k-Publications: Oxygen kinetics]]
* [[O2k-Publications: Oxygen kinetics]]
* [[O2k-Publications: Hypoxia]]
* [[O2k-Publications: Hypoxia]]

Revision as of 18:16, 20 December 2021

Publications in the MiPMap
Scandurra FM, Gnaiger E (2010) Cell respiration under hypoxia: facts and artefacts in mitochondrial oxygen kinetics. Adv Exp Med Biol 662:7-25.

ยป PMID: 20204766, Bioblast pdf

Scandurra FM, Gnaiger Erich (2010) Adv Exp Med Biol

Abstract: When oxygen supply to tissues is limiting, mitochondrial respiration and ATP production are compromised. To assess the bioenergetic consequences under normoxia and hypoxia, quantitative evaluation of mitochondrial oxygen kinetics is required. Using high-resolution respirometry, the "apparent Km" for oxygen or p50 of respiration in 32D cells was determined at 0.05 +/- 0.01 kPa (0.4 mmHg, 0.5 ยตM, 0.25 % air saturation). Close agreement with p50 of isolated mitochondria indicates that intracellular gradients are small in small cells at routine activity. At intracellular pO2 <2 kPa (15 mmHg, 10 % air saturation) in various tissues under normoxia, respiration is limited by >2 % with a p50 of 0.05 kPa. Over-estimation of p50 at 0.4 kPa (3 mmHg) would imply significant (>17 %) oxygen limitation of respiration under intracellular normoxia. Based on a critical review, we conclude that p50 ranges from 0.01 to 0.10 kPa in mitochondria and small cells in the absence of inhibitors of cytochrome c oxidase, whereas experimental artefacts explain the controversial >200-fold range of p50 in the literature on mitochondrial oxygen kinetics.


โ€ข O2k-Network Lab: AT Innsbruck Gnaiger E, AT Innsbruck Oroboros


Labels: MiParea: Respiration, Instruments;methods 


Organism: Mouse  Tissue;cell: Blood cells  Preparation: Isolated mitochondria, Intact cells 

Regulation: Oxygen kinetics  Coupling state: LEAK, ROUTINE, OXPHOS, ET 

HRR: Oxygraph-2k 

Alert2020, MitoFit 2021 AmR-O2 

Cited by

  • Komlรณdi T, Sobotka O, Gnaiger E (2021) Facts and artefacts on the oxygen dependence of hydrogen peroxide production using Amplex UltraRed. Bioenerg Commun 2021.4. https://doi:10.26124/BEC:2021-0004

O2k-Publications