MiPNet15.03 O2k-MultiSensor-ISE: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{OROBOROS navigation line page name}} | {{OROBOROS navigation line page name}} | ||
{{Publication | {{Publication | ||
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k-MultiSensor system with ion selective electrodes (ISE). | |title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k-MultiSensor system with ion selective electrodes (ISE). [[Media:MiPNet15.03_MultiSensor-ISE.pdf|Β»Bioblast pdfΒ«]] | ||
|info=[http://www.bioblast.at/index.php/File:MiPNet15.03_MultiSensor-ISE.pdf Versions] | |||
|authors=OROBOROS | |authors=OROBOROS | ||
|year=2014-03-06 | |year=2014-03-06 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract= | |abstract=Fasching M, Gnaiger E (2014) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(05):1-20. | ||
The O2k-MultiSensor extension of the OROBOROS | The O2k-MultiSensor extension of the OROBOROS O2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP<sup>+</sup>, TPMP<sup>+</sup>), Ca<sup>2+</sup>, Mg<sup>2+</sup>, etc. This manual describes the handling and application of this ISE system. | ||
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | :>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | ||
|keywords=HRR, MultiSensor | |keywords=HRR, MultiSensor |
Revision as of 11:53, 18 May 2015
Template:OROBOROS navigation line page name
O2k-MultiSensor system with ion selective electrodes (ISE). Β»Bioblast pdfΒ« |
Β» Versions
OROBOROS (2014-03-06) Mitochondr Physiol Network
Abstract: Fasching M, Gnaiger E (2014) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(05):1-20.
The O2k-MultiSensor extension of the OROBOROS O2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system.
- >> Product: OROBOROS Oxygraph-2k, O2k-Catalogue
β’ Keywords: HRR, MultiSensor
β’ O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels: MiParea: Instruments;methods
HRR: Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
O2k-MultiSensor, DatLab