Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Stopper\black PEEK\conical Shaft\central Port"

From Bioblast
Line 14: Line 14:
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluorescence LED2-Module]]). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See [[MiPNet12.06]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluorescence LED2-Module]]). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See [[MiPNet12.06]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.


<br> {{Technical service}}
[[Categiry:Technical service]]

Revision as of 17:11, 13 February 2015

                



Stopper\black PEEK\conical Shaft\central Port

O2k-Catalogue

Description Stopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings (O-ring\Viton\12x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules (O2k-Fluorescence LED2-Module).
Product ID 24000-01
Type O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper
Link O2k-Fluorescence LED2-Module
Image
Stopper black PEEK conical Shaft central Port.JPG

Stoppers for O2k-Core

2 black stoppers in O2k-Assembly Kit; alternatively, 2 white stoppers Stopper\white PVDF\conical Shaft\central Port. The stoppers are placed in the O2k-Service Box for shipment of the O2k-Core.

O2k-Manual

Stoppers and optical measurements

Use only black PEEK stoppers in conjunction with optical measurements (O2k-Fluorescence LED2-Module). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See MiPNet12.06 for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.

Categiry:Technical service