Stopper\black PEEK\conical Shaft\central Port: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules ([[O2k- | |description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules ([[O2k-Fluo_LED2-Module]]). | ||
Two units of this item are standard components of the [[O2k-Assembly Kit]] ([[O2k-Core]]). | Two units of this item are standard components of the [[O2k-Assembly Kit]] ([[O2k-Core]]). | ||
|product id=24000-01 | |product id=24000-01 | ||
|product type=O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper | |product type=O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper | ||
|info=[[O2k- | |info=[[O2k-Fluo_LED2-Module]] | ||
|product image=[[Image:Stopper black PEEK conical Shaft central Port.JPG|right|180px]] | |product image=[[Image:Stopper black PEEK conical Shaft central Port.JPG|right|180px]] | ||
}} | }} | ||
Line 14: | Line 14: | ||
== O2k-Manual == | == O2k-Manual == | ||
=== Stoppers and optical measurements === | === Stoppers and optical measurements === | ||
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k- | Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluo_LED2-Module]]). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See [[MiPNet12.06]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers. | ||
[[Category:Technical service]] | [[Category:Technical service]] |
Revision as of 10:20, 15 June 2015
Stopper\black PEEK\conical Shaft\central Port
Description | Stopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings (O-ring\Viton\12x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules (O2k-Fluo_LED2-Module).
Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core). |
---|---|
Product ID | 24000-01 |
Type | O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper |
Link | O2k-Fluo_LED2-Module |
Image |
Stoppers for O2k-Core
The stoppers are placed in the O2k-Service Box for shipment of the O2k-Core.
O2k-Manual
Stoppers and optical measurements
Use only black PEEK stoppers in conjunction with optical measurements (O2k-Fluo_LED2-Module). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See MiPNet12.06 for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.