Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Volume-Calibration Ring"

From Bioblast
m
 
(30 intermediate revisions by 10 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description='''Volume-Calibration Ring''' (A or B) for PVDF or PEEK O2k-Stoppers, white; included in stoppers, e.g. [[Stopper\black PEEK\conical Shaft\central Port]].
__TOC__
|product id=2432A-01 or 2432B-01
{{MitoPedia without banner
|product type=O2k, Stopper
|abbr=
|info=Previous Product ID: 2413A-24 or 2413B-24. [[MiPNet12.06]], [[Volume calibration ring (technical service)]]
|description=[[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]'''Volume-Calibration Ring''' (A or B) PVDF for O2k-Stoppers (2-mL [[O2k-chamber]]), white; attached to the [[Stopper\black PEEK\conical Shaft\central Port |stoppers]].
|product image=[[File:Volume calibration ring A+B for PVDF Stopper.jpg|right|180px|link=]]
|info=[https://www.oroboros.at/index.php/product/volume-calibration-ring/ '''Product details and purchase information''']
}}
__TOC__
== Technical support ==
 
::: '''Volume calibration of the [[O2k-chamber]]'''
::::* Loosen the stopper fixation rings (A) and (B) with the Allen key (OroboPOS-Service Kit).
::::* Follow the instructions in the O2k-Manual: [[MiPNet22.11 O2k-FluoRespirometer manual]]
::::* Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.
 
== Keywords ==
{{Template:Keywords: Chamber volume}}
 
 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}
}}
If several [[O2k]] instruments are used, the chambers may be labelled (in [[DatLab]]) A, B, C, D, ..., but volume calibration rings are available only with labels A or B.

Latest revision as of 11:53, 11 November 2020


                  


O2k-Open Support

Volume-Calibration Ring



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Volume calibration ring A+B PVDF for Stopper.jpg

Volume-Calibration Ring (A or B) PVDF for O2k-Stoppers (2-mL O2k-chamber), white; attached to the stoppers.


Reference: Product details and purchase information


Technical support

Volume calibration of the O2k-chamber
  • Loosen the stopper fixation rings (A) and (B) with the Allen key (OroboPOS-Service Kit).
  • Follow the instructions in the O2k-Manual: MiPNet22.11 O2k-FluoRespirometer manual
  • Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.

Keywords


Questions.jpg


Click to expand or collaps



MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry