Difference between revisions of "MiPNet14.06 Instrumental O2 background"
From Bioblast
m (Reverted edits by Iglesias-Gonzalez Javier (talk) to last revision by Gnaiger Erich) Tag: Rollback |
|||
Line 1: | Line 1: | ||
{{Template:OROBOROS support page name}} | |||
{{Publication | {{Publication | ||
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. | |title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. | ||
Line 10: | Line 11: | ||
|mipnetlab=AT_Innsbruck_Oroboros | |mipnetlab=AT_Innsbruck_Oroboros | ||
}} | }} | ||
== Keywords == | == Keywords == | ||
{{Template:Keywords: Chamber volume}} | {{Template:Keywords: Chamber volume}} | ||
Line 27: | Line 21: | ||
<br/> | <br/> | ||
<br/> | <br/> | ||
{{Labeling | |||
|area=Respiration, Instruments;methods | |||
|instruments=Oxygraph-2k, O2k-Manual | |||
|additional=DatLab, O2k-SOP, DL7, System | |||
}} |
Revision as of 11:56, 26 January 2021
MiPNet14.06 Instrumental O2 background |
O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. |
» » Versions
Oroboros (2020-04-16) Mitochondr Physiol Network
Abstract: Fasching M, Gnaiger E (2020) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(08):1-16.
- » Current O2k-series: NextGen-O2k Series XB and O2k Series J
- » Current software versions DatLab 8.0: MitoPedia: DatLab
- Further details: » MitoPedia: O2k-Open Support
- » Product: O2k-FluoRespirometer, O2k-Catalogue
• O2k-Network Lab: AT_Innsbruck_Oroboros
Keywords
- »Bioblast links: Chamber volume - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>
- » Volume
- Units: Liter [L]; 1 L = 1 dm3 = 10-3 m3; 1 mL = 1 cm3; 1 µL = 1 mm3
- » Volume
- On chamber volume
- Components of the experimental O2k-chambers
- » Stirrer-Bar\white PVDF\15x6 mm
- » Stirrer-Bar sV\white PVDF\11.5x6.2 mm
- » Stopper\black PEEK\conical Shaft\central Port
- » Stopper sV\black PEEK\conical Shaft\central Port
- » O-ring\Viton\12.5x1 mm
- » O-ring sV\Viton\9.5x1 mm
- » Volume-Calibration Ring
- » Volume-Calibration Ring sV
- » Stopper-Spacer
- » Cover-Slip\black
- » O2k-Chamber Holder
- » O2k-Chamber Holder sV
- » OroboPOS-Holder
- » OroboPOS-Holder sV
- Maintencance
Acknowledgements
Labels: MiParea: Respiration, Instruments;methods
HRR: Oxygraph-2k, O2k-Manual
DatLab, O2k-SOP, DL7, System